Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
Clin Infect Dis ; 73(7): e1870-e1877, 2021 10 05.
Article in English | MEDLINE | ID: covidwho-1455249

ABSTRACT

BACKGROUND: We evaluated severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) surface and air contamination during the coronavirus disease 2019 (COVID-19) pandemic in London. METHODS: Prospective, cross-sectional, observational study in a multisite London hospital. Air and surface samples were collected from 7 clinical areas occupied by patients with COVID-19 and a public area of the hospital. Three or four 1.0-m3 air samples were collected in each area using an active air sampler. Surface samples were collected by swabbing items in the immediate vicinity of each air sample. SARS-CoV-2 was detected using reverse-transcription quantitative polymerase chain reaction (PCR) and viral culture; the limit of detection for culturing SARS-CoV-2 from surfaces was determined. RESULTS: Viral RNA was detected on 114 of 218 (52.3%) surfaces and in 14 of 31 (38.7%) air samples, but no virus was cultured. Viral RNA was more likely to be found in areas immediately occupied by COVID-19 patients than in other areas (67 of 105 [63.8%] vs 29 of 64 [45.3%]; odds ratio, 0.5; 95% confidence interval, 0.2-0.9; P = .025, χ2 test). The high PCR cycle threshold value for all samples (>30) indicated that the virus would not be culturable. CONCLUSIONS: Our findings of extensive viral RNA contamination of surfaces and air across a range of acute healthcare settings in the absence of cultured virus underlines the potential risk from environmental contamination in managing COVID-19 and the need for effective use of personal protective equipment, physical distancing, and hand/surface hygiene.


Subject(s)
COVID-19 , SARS-CoV-2 , Cross-Sectional Studies , Delivery of Health Care , Humans , London/epidemiology , Pandemics , Prospective Studies
2.
Acta Clin Belg ; 77(2): 368-376, 2022 Apr.
Article in English | MEDLINE | ID: covidwho-1081271

ABSTRACT

INTRODUCTION: We present the results of the COVID-19 rule-out protocol at Ghent University Hospital, a step-wise testing approach which included repeat NFS SARS-CoV-2 rRT-PCR, respiratory multiplex RT-PCR, low-dose chest CT and bronchoscopy with BAL to confirm or rule-out SARS-CoV-2 infection in patients admitted with symptoms suggestive of COVID-19. RESULTS: Between 19 March 2020 and 30 April 2020, 455 non-critically ill patients with symptoms suspect for COVID-19 were admitted. The initial NFS for SARS-CoV-2 rRT-PCR yielded 66.9%, the second NFS 25.4% and bronchoscopy with BAL 5.9% of total COVID-19 diagnoses. In the BAL fluid, other respiratory pathogens were detected in 65% (13/20) of the COVID-19 negative patients and only in 1/7 COVID-19 positive patients. Retrospective antibody testing at the time around BAL sampling showed a positive IgA or IgG in 42.9 % of the COVID-19 positive and 10.5% of the COVID-19 negative group. Follow-up serology showed 100% COVID-19 positivity in the COVID-19 positive group and 100% IgG negativity in the COVID-19 negative group. CONCLUSION: In our experience, bronchoscopy with BAL can have an added value to rule-in or rule-out COVID-19 in patients with clinical and radiographical high-likelihood of COVID-19 and repeated negative NFS testing. Furthermore, culture and respiratory multiplex PCR on BAL fluid can aid to identify alternative microbial etiological agents in this group. Retrospective analysis of antibody development in this selected group of patients suggests that the implementation of serological assays in the routine testing protocol will decrease the need for invasive procedures like bronchoscopy.


Subject(s)
COVID-19 , Bronchoscopy , COVID-19/diagnosis , Humans , Retrospective Studies , SARS-CoV-2 , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL